Dec-2025 Get Totally Free Updates on 5V0-22.23 Dumps PDF Questions [Q30-Q47]

Share

Dec-2025 Get Totally Free Updates on 5V0-22.23 Dumps PDF Questions

Prepare With Top Rated High-quality 5V0-22.23 Dumps For Success in 5V0-22.23 Exam


The VMware vSAN Specialist (v2) certification exam is ideal for IT professionals who want to upgrade their skills set and improve their career prospects. By obtaining this certification, you can showcase your expertise in vSAN technology, which enhances your credibility and opens up new career opportunities. Besides, this certification establishes you as a trusted and reliable professional in the eyes of employers, customers, and peers.

 

NEW QUESTION # 30
After a planned power outage, an administrator decided to restart the vSAN cluster manually.
What is the correct sequence of steps for the administrator to follow after powering on the ESXi hosts?

  • A. 1. Exit all hosts from maintenance mode.
    2. Run the python reboot helper script only on one ESXi host to recover the cluster.
    3. Enable cluster member updates from vCenter Server on all ESXi hosts.
  • B. 1. Exit all hosts from maintenance mode.
    2. Enable cluster member updates from vCenter Server only on one ESXi host.
    3. Run the python reboot helper script only on one ESXi host to recover the cluster.
  • C. 1. Enable cluster member updates from vCenter Server on all ESXi hosts.
    2. Run the python reboot helper script on all ESXi hosts to recover the cluster.
    3. Exit all hosts from maintenance mode.
  • D. 1. Enable cluster member updates from vCenter Server only on one ESXi host.
    2. Run the python reboot helper script only on one ESXi host to recover the cluster.
    3. Exit all hosts from maintenance mode.

Answer: D

Explanation:
Explanation
This is the sequence of steps recommended by VMware for manually restarting the vSAN cluster after a planned power outage. The steps are as follows:
Enable cluster member updates from vCenter Server only on one ESXi host. This will allow the host to receive the latest cluster membership information from vCenter Server and avoid any conflicts or inconsistencies with other hosts. The command to enable cluster member updates is esxcfg-advcfg -s 1
/VSAN/IgnoreClusterMemberListUpdates.
Run the python reboot helper script only on one ESXi host to recover the cluster. This will prepare the cluster for a manual restart by partitioning the cluster and ensuring that all hosts have consistent metadata. The command to run the python reboot helper script is python
/usr/lib/vmware/vsan/bin/reboot_helper.py prepare.
Exit all hosts from maintenance mode. This will allow the hosts to resume normal operations and join the vSAN cluster. The command to exit maintenance mode is esxcli system maintenanceMode set -e false.
The other options are incorrect for the following reasons:
B, exit all hosts from maintenance mode, run the python reboot helper script only on one ESXi host to recover the cluster, and enable cluster member updates from vCenter Server on all ESXi hosts, is incorrect because exiting all hosts from maintenance mode before running the python reboot helper script can cause data inconsistency or corruption, as the hosts may not have the latest metadata or cluster membership information. Enabling cluster member updates from vCenter Server on all ESXi hosts is also unnecessary and can cause conflicts or inconsistencies with other hosts.
C, exit all hosts from maintenance mode, enable cluster member updates from vCenter Server only on one ESXi host, and run the python reboot helper script only on one ESXi host to recover the cluster, is incorrect because exiting all hosts from maintenance mode before running the python reboot helper script can cause data inconsistency or corruption, as the hosts may not have the latest metadata or cluster membership information.
D, enable cluster member updates from vCenter Server on all ESXi hosts, run the python reboot helper script on all ESXi hosts to recover the cluster, and exit all hosts from maintenance mode, is incorrect because enabling cluster member updates from vCenter Server on all ESXi hosts is unnecessary and can causeconflicts or inconsistencies with other hosts. Running the python reboot helper script on all ESXi hosts concurrently can also cause a race condition that can result in unexpected outcomes.
References:
Manually Shut Down and Restart the vSAN Cluster
Restart the vSAN Cluster


NEW QUESTION # 31
An administrator is tasked to create a Kerberos secured NFS v4.1 file share.
Which information is minimally required during the configuration of the File Service?

  • A. Kerberos Server, User Account, Password
  • B. Active Directory Domain, User Account, Password
  • C. Active Directory Domain. Organizational Unit, User Account. Password
  • D. Organizational Unit, User Account, Password

Answer: B

Explanation:
Explanation
To create a Kerberos secured NFS v4.1 file share, the administrator needs to provide the following information during the configuration of the File Service:
Active Directory Domain: The domain name of the Active Directory server that provides Kerberos authentication service for the NFS server and clients. For example, example.com.
User Account: The user name of the Active Directory account that has permissions to join the NFS server to the domain and create service principal names (SPNs) for the NFS server. For example, [email protected].
Password: The password of the Active Directory account that is used for authentication. For example, P@ssw0rd.
These information are required to enable Kerberos security for NFS 4.1 and allow the NFS server to obtain a Kerberos ticket from the Active Directory server. The administrator also needs to specify the NFS share name, path, and access permissions1 References: 1: VMware vSphere Storage Guide, page 118


NEW QUESTION # 32
What are two prerequisites for using the TRIM and UNMAP capability of vSAN? (Choose two.)

  • A. The VM quest operating system supports ATA TRIM or SCSI UNMAP capability
  • B. Deduplication and compression are enabled.
  • C. Change the Object Space Reservation to 100.
  • D. TRIM and UNMAP is enabled.
  • E. The vSAN cluster is an all-flash architecture.

Answer: D,E

Explanation:
Explanation
The two prerequisites for using the TRIM and UNMAP capability of vSAN are:
B: The vSAN cluster is an all-flash architecture. TRIM and UNMAP are only supported on all-flash vSAN clusters, as they can reclaim space from flash devices that use thin provisioning. TRIM and UNMAP are not supported on hybrid vSAN clusters, as they cannot reclaim space from magnetic disks that use thick provisioning1.
D: TRIM and UNMAP is enabled. TRIM and UNMAP are disabled by default in vSAN, as they might have a performance impact on some workloads. To enable TRIM and UNMAP on a vSAN cluster, the administrator must use the following RVC command: vsan.unmap_support -enable2. After enabling TRIM and UNMAP, the administrator must power off and then power on all VMs that use the vSAN datastore.


NEW QUESTION # 33
A vSAN administrator needs to enable vSAN ESA.
Which two requirements need to be met? (Choose two.)

  • A. vSAN ReadyNodes configuration
  • B. vSAN Standard license
  • C. vSAN Build Your Own configuration
  • D. vSAN Witness Appliance
  • E. vSAN Advanced license

Answer: A,B

Explanation:
Explanation
To enable vSAN ESA, two requirements that need to be met are: vSAN Standard license or higher, and vSAN ReadyNodes configuration. vSAN Standard license or higher is required to use vSAN ESA, as it is a feature that is only available in vSAN 8.0 or later versions. vSAN ESA is an optional, alternative architecture to vSAN OSA that is designed to process and store data with higher efficiency, scalability, and performance.
vSAN ReadyNodes configuration is required to use vSAN ESA, as it is a hardware configuration that is pre-configured, tested, and certified for VMware Hyper-Converged Infrastructure Software. Each vSAN ReadyNode is optimally configured for vSAN ESA with the required amount of CPU, memory, network, and storage NVMe devices. The other options are not correct. vSAN Build Your Own configuration is not supported for vSAN ESA, as it might not meet the hardware requirements or compatibility for vSAN ESA.
vSAN Witness Appliance is not required to use vSAN ESA, as it is only needed for stretched cluster or two-node cluster configurations. References: vSAN Express Storage Architecture; vSAN ReadyNode Hardware Guidance


NEW QUESTION # 34
During yesterday's business hours, a cache drive failed on one of the vSAN OSA nodes. The administrator reached out to the manufacturer and received a replacement drive the following day. When the drive failed, vSAN started a resync to ensure the health of the data, and all objects are showing a healthy and compliant state. The vSAN administrator needs to replace the failed cache drive.
Which set of steps should the vSAN administrator take?

  • A. Place the disk group into maintenance mode, and select Full Data Migration. Then, physically replace the failed cache device. Afterwards. vSAN will rebuild the disk group automatically.
    C Remove the existing vSAN disk group and physically replace thedevice. Thencheck to verify that the ESXi host automatically detects the new device Afterwardsmanually recreate the Disk Group
  • B. Physically replace the failed cache device, and vSAN will automatically create a new disk group. Then, remove the disk group with the failed device.
  • C. Physically replace the failed cache device, and vSAN will automatically allocate the storage. Then, rebalance the cache layer.

Answer: C

Explanation:
Explanation
To replace a failed cache drive in a vSAN OSA cluster, the vSAN administrator should remove the existing vSAN disk group and physically replace the device. Then check to verify that the ESXi host automatically detects the new device Afterwards manually recreate the Disk Group. This is because when a cache drive fails, it affects the entire disk group that contains it, and vSAN does not allow removing only the cache drive from a disk group. Therefore, the administrator must remove the whole disk group before replacing the cache drive, and then recreate it with the new cache drive and the existing capacity drives. The other options are not correct. Physically replacing the failed cache drive without removing the disk group first might cause errors or inconsistencies in vSAN configuration. vSAN will not automatically create a new disk group or allocate storage after replacing a cache drive, as these actions require manual intervention from the administrator.
Rebalancing the cache layer is not necessary after replacing a cache drive, as vSAN will automatically distribute data across all devices in the disk group. References: Replace a Flash Caching Device on a Host; How to manually remove and recreate a vSAN disk group using esxcli


NEW QUESTION # 35
What is the minimum required number of hosts to provide data redundancy for a vSAN stretched cluster using dual-site mirroring and local protection with 1 failure - RAID-1 (Mirroring)?

  • A. 3 hosts
  • B. 4 hosts
  • C. 6 hosts
  • D. 3 hosts

Answer: C

Explanation:
Explanation
The minimum required number of hosts to provide data redundancy for a vSAN stretched cluster using dual-site mirroring and local protection with 1 failure - RAID-1 (Mirroring) is six hosts. This is because a vSAN stretched cluster requires at least three hosts per site, and each site must have enough hosts to tolerate one host failure. Therefore, the minimum configuration is three hosts per site, plus one witness host at a third site, for a total of six hosts. References: [VMware vSAN Specialist v2 EXAM 5V0-22.23], page 14


NEW QUESTION # 36
The Resyncing Objects view in the vCenter UI reports that some objects are currently resyncing.
Which two actions would cause this situation? (Choose two.)

  • A. A change to the storage policy is applied to the objects.
  • B. A host failure occurs in the cluster
  • C. DRS is relocatingVMs between vSAN nodes.
  • D. HA Virtual Machine Monitoring forced a VM to reboot.
  • E. VM snapshot is being deleted.

Answer: A,B

Explanation:
Explanation
Two actions that would cause some objects to be currently resyncing are:
A change to the storage policy is applied to the objects. This action triggers a resynchronization of objects to make them compliant with the new policy settings, such as FTT, RAID level, stripe width, etc. The resynchronization process copies data from one host to another to create or update replicas or parity segments.
A host failure occurs in the cluster. This action causes some objects to become non-compliant with their storage policy, as they lose one or more replicas or parity segments due to the host failure. The resynchronization process rebuilds the missing components on other hosts in the cluster to restore compliance and availability.References: : VMware vSphere Storage Guide, page 129 : Monitor the Resynchronization Tasks in the vSAN Cluster 1 : VMware vSAN Specialist v2 Exam Preparation Guide, page 13


NEW QUESTION # 37
The vSphere Client reports that the state of some components stored on the vSAN datastore are in the reconfiguring state.
Which situation causes components to enter this state?

  • A. The cluster is recovering from a vSAN failure.
  • B. A host in the cluster enters maintenance mode.
  • C. The applied storage policy is modified.
  • D. Additional storage capacity is added to the cluster.

Answer: C

Explanation:
Explanation
The reconfiguring state indicates that some components stored on the vSAN datastore are being moved or resized to meet a new storage policy requirement. This state can occur when the applied storage policy is modified, such as changing the number of failures to tolerate, stripe width, or object space reservation. The other situations will not cause components to enter this state. References: [VMware vSAN Specialist v2 EXAM 5V0-22.23], page 31


NEW QUESTION # 38
In which type of environment is vSAN storage used as a mandatory, primary storage?

  • A. VMware Horizon
  • B. TanzuKubernetes Grid Integrated Edition
  • C. VMware Cloud on AWS
  • D. VMware Aria Automation

Answer: C

Explanation:
Explanation
VMware Cloud on AWS is a service that delivers a fully managed VMware SDDC on AWS infrastructure. It uses vSAN as the mandatory, primary storage for the SDDC clusters. vSAN provides a high-performance, resilient, and secure shared storage solution for the VMware Cloud on AWS environment. The other options are not correct, as vSAN is not mandatory or primary for them. VMware Horizon, VMware Aria Automation, and Tanzu Kubernetes Grid Integrated Edition can use vSAN as an optional or secondary storage solution, but they can also use other types of storage. References: , section 1.1; , section 1.2


NEW QUESTION # 39
A vSAN administrator encounters a non-compliant virtual machine and the compliance status of some of its objects is noncompliant. vSAN is able to locate a full replica of 55% of the votes for the noncompliant objects.
What will vSAN do with the virtual machine?

  • A. Mark the virtual machine as inaccessible as vSAN is not able to locate more than 60% of the votes for the objects
  • B. Mark the virtual machine as orphaned
  • C. Mark the virtual machine as compliant and automatically recover the noncompliant objects
  • D. Power off the virtual machine

Answer: C

Explanation:
Explanation
If vSAN is able to locate a full replica of 55% of the votes for the noncompliant objects of a virtual machine, vSAN will mark the virtual machine as compliant and automatically recover the noncompliant objects. This is because vSAN uses a quorum-based algorithm to determine object availability and compliance. An object is considered available if more than 50% of its votes are accessible, and compliant if it meets its assigned storage policy requirements. In this case, since 55% of the votes are accessible, vSAN can access a full replica of each object and restore its compliance state by rebuilding any missing or corrupted components. The other options are not correct. vSAN will not power off, mark as inaccessible, or mark as orphaned a virtual machine that has more than 50% of its votes accessible, as these actions would result in unnecessary downtime or data loss.
References: Object States That Indicate Problems in vSAN; Accessibility of Virtual Machines Upon a Failure in vSAN


NEW QUESTION # 40
What is the purpose of the TRIM/UNMAP process?

  • A. Repairs internal cache errors
  • B. Collects vSAN log files
  • C. Deletes orphaned snapshots
  • D. Reclaims disk space

Answer: D

Explanation:
Explanation
The purpose of the TRIM/UNMAP process is to reclaim disk space that is no longer used by the guest operating system or the virtual machine. TRIM and UNMAP are commands that allow the guest operating system to inform the underlying storage layer that certain blocks are no longer in use and can be freed up. This process helps to improve storage efficiency and utilization,especially for thin-provisioned disks that grow dynamically as data is written to them. The other options are not correct. The TRIM/UNMAP process does not collect vSAN log files, repair internal cache errors, or delete orphaned snapshots. These are different tasks that are performed by other tools or processes. References: Enabling TRIM/UNMAP Commands for VMware Cloud on AWS Clusters; Reclaiming guest OS storage in VMware vSAN 6.7 U1 with TRIM/UNMAP process


NEW QUESTION # 41
A customer has deployed a new vSAN cluster with the following configuration:
5 x vSAN ReadyNodes
All Flash
12 TB Raw Storage
vSAN 8 is deployed with ESA.
New VMs are configured with a RAID-5 VM policy.
Which statement is accurate?

  • A. vSAN will use a 4+1 RAID-5 data placement scheme with parity will be used
  • B. vSAN will spread the components across all of the disk groups
  • C. RAID 5 will provide an FTT=2 level of protection in this case
  • D. vSAN will use a 2+1 RAID-5 data placement scheme with parity will be used

Answer: A

Explanation:
Explanation
vSAN will use a 4+1 RAID-5 data placement scheme with parity will be used is the correct answer because vSAN 8 ESA uses adaptive RAID-5 erasure coding that depends on the number of hosts in the cluster. If the cluster has 6 or more hosts, vSAN will use a 4+1 RAID-5 scheme, where the data is written as a stripe of 4 data bits and 1 parity bit across 5 hosts. This provides a failure tolerance of 1 (FTT=1) and a space efficiency of 1.25x. If the cluster has less than 6 hosts (3 to 5), vSAN will use a 2+1 RAID-5 scheme, where the data is written as a stripe of 2 data bits and 1 parity bit across 3 hosts. This also provides a failure tolerance of 1 (FTT=1) but a space efficiency of 1.5x. In this case, the cluster has 5 hosts, so vSAN will use the 4+1 RAID-5 scheme.
The other options are incorrect for the following reasons:
A, vSAN will use a 2+1 RAID-5 data placement scheme with parity will be used, is incorrect because vSAN will only use this scheme if the cluster has less than 6 hosts but more than 2 hosts. In this case, the cluster has 5 hosts, so vSAN will use the 4+1 RAID-5 scheme.
B, RAID 5 will provide an FTT=2 level of protection in this case, is incorrect because RAID 5 can only provide an FTT=1 level of protection, regardless of the number of hosts or the data placement scheme.
To achieve an FTT=2 level of protection, vSAN would need to use RAID 6 erasure coding, which requires at least 6 hosts in the cluster.
D, vSAN will spread the components across all of the disk groups, is incorrect because vSAN will not necessarily spread the components across all of the disk groups in the cluster. vSAN will only spread the components across as many disk groups as needed to meet the storage policy requirements and to balance the load and capacity. In this case, vSAN will only need to spread the components across 5 disk groups for each stripe of RAID-5 data. References:
VMware vSAN Specialist v2 Exam Preparation Guide, page 11
Adaptive RAID-5 Erasure Coding with the Express Storage Architecture in vSAN 8


NEW QUESTION # 42
Which two actions are recommended when adding a host to a vSAN cluster? (Choose two.)

  • A. Reference the VMware Compatibility Guide
  • B. Create uniformly-configured hosts
  • C. Disable vSphere Cluster Services
  • D. Disable vSphere High Availability (HA)
  • E. Disable vSAN performance service

Answer: A,B

Explanation:
Explanation
When adding a host to a vSAN cluster, it is recommended to create uniformly-configured hosts and reference the VMware Compatibility Guide. These actions will ensure that the host meets the hardware and software requirements for vSAN, and that it can work seamlessly with the existing hosts in the cluster.
Uniformly-configured hosts have the same number and type of disk groups, cache devices, capacity devices, network adapters, and drivers. The VMware Compatibility Guide provides a list of certified components and firmware versions that are compatible with vSAN. The other options are not recommended, as they can cause disruption or degradation of the vSAN cluster services. Disabling vSAN performance service, vSphere Cluster Services, or vSphere High Availability (HA) can affect the monitoring, availability, and load balancing of the cluster.


NEW QUESTION # 43
A vSAN administrator is investigating vSAN performance related problems but cannot find any vSAN performance statistics on the cluster summary page.
Why is this situation occurring?

  • A. The administrator has read-only permissions on the cluster level.
  • B. vSAN performance service is not enabled.
  • C. The vRealize Operations Manager is not integrated with vSAN cluster.
  • D. vSAN performance statistics are only available via CLI.

Answer: B

Explanation:
Explanation
The reason why the vSAN administrator cannot find any vSAN performance statistics on the cluster summary page is that the vSAN performance service is not enabled. The vSAN performance service is a feature that collects and analyzes performance metrics and displays them in graphical charts in vCenter. The vSAN performance service must be turned on manually for each vSAN cluster, as it is not enabled by default. The other options are not correct. The integration of vRealize Operations Manager with the vSAN cluster is not required to view vSAN performance statistics, as they are available in vCenter. The administrator's permissions on the cluster level do not affect the visibility of vSAN performance statistics, as they are accessible to any user who can view the cluster. vSAN performance statistics are not only available via CLI, as they can also be viewed in vCenter using the vSAN performance service. References: About the vSAN Performance Service; Enable or Disable the Performance Service


NEW QUESTION # 44
An administrator is performing maintenance on the hosts in a four-node vSAN cluster and has selected the
"Ensure Accessibility" maintenance mode option. All VMs are running with the Default Storage Policy which has not been modified from the default settings.
While one of the hosts in the cluster is down for firmware upgrade, a second host suddenly loses network connectivity to the remaining hosts.
How will the cluster be affected?

  • A. All VMs in the cluster will be inaccessible
  • B. Cluster will still be fully operational
  • C. The backend performance metrics will be lost
  • D. VMs might experience data loss

Answer: D

Explanation:
Explanation
If two hosts in a four-node vSAN cluster are down, the cluster might experience data loss because the default storage policy has a Primary level of failures to tolerate (PFTT) of 1, which means that vSAN can tolerate only one host failure. The Ensure accessibility maintenance mode option does not guarantee full data redundancy, but only ensures that all accessible VMs remain accessible. If another host fails while one host is in maintenance mode, some VMs might lose access to their data components and become unavailable or corrupted. References: vSAN Maintenance Mode Options; vSAN Cluster Configuration Limits


NEW QUESTION # 45
All of the virtual machines running on a hybrid vSAN datastore have this storage policy assigned:
Failures to Tolerate (FTT) rule is set to "2 Failures - RAID-1 (Mirroring)" The vSAN administrator needs to reduce the amount of vSAN datastore capacity the virtual machines will consume.
Which action should the vSAN administrator take to meet this goal?

  • A. Change the FTT rule to "1 Failure - RAID-1 (Mirroring)", and select "Now" for Reapply to VMs
  • B. Add the "Flash read cache reservation" rule to the storage policy, and set to 0%
  • C. Modify the FTT rule to "2 Failures - RAID-5 (Erasure Coding)"
  • D. Disable Operations reserve and Host rebuild reserve and click "Apply"

Answer: A

Explanation:
Explanation
To reduce the amount of vSAN datastore capacity the virtual machines will consume, the vSAN administrator should change the FTT rule to "1 Failure - RAID-1 (Mirroring)", and select "Now" for Reapply to VMs. This action will reduce the number of replicas for each object from three to two, and thus free up some space on the vSAN datastore. The other options are not correct, as they will not reduce the capacity consumption.
Modifying the FTT rule to "2 Failures - RAID-5 (Erasure Coding)" will not work for a hybrid vSAN cluster, as erasure coding is only supported for all-flash clusters. Adding the "Flash read cache reservation" rule to the storage policy, and setting to 0% will not affect the capacity layer, as it only controls the amount of flash cache reserved for each object. Disabling Operations reserve and Host rebuild reserve and clicking "Apply" will not change the actual space used by the objects, as these reserves are only logicalsettings that affect how much free space is reported by vSAN. References: 1, page 9; , section 4.3


NEW QUESTION # 46
What are two characteristics of a durability component in vSAN? (Choose two.)

  • A. Better Performance
  • B. Faster resynchronization
  • C. Better Availability
  • D. Faster snapshot creation
  • E. Better Storage utilization

Answer: B,C

Explanation:
Explanation
A durability component is a temporary component that is created when a host or disk group is placed in maintenance mode with the Ensure data accessibility option, or when a host or disk group fails unexpectedly.
A durability component improves the availability of data by maintaining the required number of failures to tolerate (FTT) until the original component is restored or rebuilt. A durability component also speeds up the resynchronization process by reducing the amount of data that needs to be copied. The other characteristics are not applicable to a durability component. References: VMware vSAN Specialist v2 EXAM 5V0-22.23, page
10, Objective 6.8; [Durability Components]


NEW QUESTION # 47
......

Get 100% Success with Latest VMware Certified Specialist - vSAN 2023 5V0-22.23 Exam Dumps: https://www.actualtestsit.com/VMware/5V0-22.23-exam-prep-dumps.html

5V0-22.23 Free Certification Exam Easy to Download PDF Format 2025: https://drive.google.com/open?id=16exNROTtIxFBgpu3ipCuEVWPFkLOSIuK